Sterisart® Universal | Gen 4
Product · Hardware / device · Operations & supply chain by Sartorius
Advanced Sterility Testing with Paperless Documentation and Contamination Control
A universal pump for membrane filtration-based sterility testing in pharmaceutical manufacturing. It features automated data transfer and integrated pressure monitoring to ensure compliant, contamination-free product release.
Category: Medical Equipment
- Interfaces and ports
- SMB, FTP, FTPS, Ping test connectivity
- Compatibility
- Sterisart canisters, 21 CFR Part 11 compliance requirements
- Technology
- Membrane filtration with peristaltic pump
- Connectivity Protocols
- SMB, FTP, FTPS
- Sensor Type
- Integrated overpressure sensor
- Application Environment
- Isolators and cleanrooms
- Closed system for membrane filtration-based sterility testing
- Integrated overpressure sensor for canister pressure maintenance
- Automated data transfer via SMB, FTP, and FTPS protocols
- Designed for use in isolators and cleanrooms
- Supports 21 CFR Part 11 compliance for electronic records
Overview
Sterisart Universal Gen 4 is a universal peristaltic pump designed for membrane filtration-based sterility testing in pharmaceutical and biopharmaceutical manufacturing. It serves as a critical tool for verifying the absence of viable microorganisms in sterile products such as parenterals, injectables, and medical devices before their release. The system features a closed filtration design that minimizes the risk of secondary contamination, ensuring reliable results and protecting patient safety. Advanced connectivity options allow for automated data transfer to servers via SMB, FTP, or FTPS, which streamlines laboratory documentation and supports compliance with 21 CFR Part 11. An integrated overpressure sensor maintains the necessary positive pressure within sterility testing canisters during operation. The pump is engineered for use in various laboratory environments, including cleanrooms and isolators.
Sterility Testing Capabilities
- Universal Application: The pump is designed for use in barrier technology, including isolators and cleanrooms, for membrane filtration-based sterility testing.
- Overpressure Monitoring: The system features an integrated overpressure sensor to maintain the positive pressure required within sterility testing canisters.
- Automated Data Transfer: The pump supports automated data transfer to servers via SMB, FTP, or FTPS to streamline laboratory documentation.
- Digital Compliance: The system ensures pharmaceutical processes meet the stringent requirements of 21 CFR Part 11 for electronic records.
Contamination Control
- Membrane Filtration Technology: The pump uses membrane filtration technology to provide precise and reliable results for verifying the absence of viable microorganisms.
- Closed System Design: The system provides a closed filtration environment to minimize the risk of secondary contamination and enhance test integrity.
- Fluid Flow Control: The pump offers precise control over fluid flow rates to ensure consistent results across different tests.
- Inhibitory Product Testing: The system is particularly suited for testing therapeutics with microbial growth-inhibiting properties, such as antibiotics.
Use cases
- Pharmaceutical manufacturers perform sterility testing on injectables and parenterals to ensure product safety before release.
- Laboratory technicians use the automated data transfer feature to sync test results directly to servers via SMB or FTP.
- Quality control teams monitor canister pressure using the integrated overpressure sensor to maintain sterility assurance levels.
- Biotech firms test therapeutics with growth-inhibiting properties using the membrane filtration system to remove inhibitory substances.
Specifications
- Interfaces and ports
- SMB, FTP, FTPS, Ping test connectivity
- Compatibility
- Sterisart canisters, 21 CFR Part 11 compliance requirements
- Technology
- Membrane filtration with peristaltic pump
- Connectivity Protocols
- SMB, FTP, FTPS
- Sensor Type
- Integrated overpressure sensor
- Application Environment
- Isolators and cleanrooms
- System Type
- Closed sterility testing system
How it works
- System Setup and Connectivity: The pump is integrated into a cleanroom or isolator environment and connected to the laboratory network via SMB, FTP, or FTPS.
- Canister Integration: Sterisart canisters are connected to the pump to create a closed system, minimizing secondary contamination risks.
- Filtration and Testing: The peristaltic pump provides precise fluid flow control for membrane filtration of the pharmaceutical product.
- Automated Documentation: Data is automatically transferred from the pump to a server or dedicated PC, removing manual guesswork from documentation.
FAQ
How does the Sterisart Universal Gen 4 handle data transfer?
The pump supports automated data transfer to servers using SMB, FTP, or FTPS protocols.
How does the system ensure pressure stability during testing?
It features an integrated overpressure sensor that maintains the indispensable positive pressure required within the canisters.
Can the Sterisart Universal Gen 4 be used in an isolator?
Yes, the pump is specifically designed for convenient use in barrier technology, including isolators.
Added by AntSpace from public sources (sartorius.com).