XFlash 7200 FIRE
Product · Hardware / device by Bruker
The new hero of elemental analysis on SEM.
An inclined 4-channel EDS detector for Scanning Electron Microscopes that delivers ultra-fast elemental mapping with an output count rate of up to 2.4 million cps. It is designed for researchers requiring high-resolution nanomaterials characterization and light element sensitivity.
Category: Medical Imaging
- Form factor
- Inclined 4-Channel EDS Detector
- Performance
- Up to 2,400,000 cps output count rate (OCR)
- Output Count Rate (OCR)
- Up to 2,400,000 cps
- Detector Type
- Inclined 4-Channel EDS Detector
- Sensor Technology
- Silicon Drift Detector (SDD)
- Up to 2,400,000 cps output count rate
- Inclined 4-channel EDS detector design
- Ultra-fast, high-resolution elemental mapping
- Outstanding light element sensitivity
Overview
XFlash 7200 FIRE is Bruker's next-generation inclined energy dispersive X-ray spectroscopy (EDS) detector designed for ultra-fast elemental analysis on Scanning Electron Microscopes (SEM). It features a unique 4-channel design with four silicon drift detector segments, each equipped with individual pulse processing to achieve high throughput. It is engineered to provide superior analytical performance and outstanding sensitivity for light elements. This tool is essential for researchers and industrial users requiring rapid and precise nanomaterials characterization and failure analysis.
Detector Architecture
- 4-Channel SDD Design: The detector utilizes a unique 4-channel design with four silicon drift detector segments to maximize signal collection.
- Individual Pulse Processing: Each of the four detector segments is equipped with its own individual pulse processing to achieve high throughput.
- Light Element Sensitivity: The system is engineered to provide outstanding sensitivity for light elements during elemental analysis.
- Integrated Platform: The detector platform combines speed, resolution, and sensitivity to redefine elemental analysis on Scanning Electron Microscopes.
Performance and Speed
- Ultra-Fast Mapping: The large active area and high throughput enable the generation of high-resolution elemental maps in seconds.
- High-Speed Characterization: The hardware is designed for rapid and precise nanomaterials characterization and failure analysis.
Use cases
- Researchers generate high-resolution elemental maps in seconds to characterize nanomaterials at the microscopic level.
- Industrial users perform rapid failure analysis using high-throughput 4-channel silicon drift detector technology.
- Scientists conduct precise elemental analysis with outstanding sensitivity for light elements on Scanning Electron Microscopes.
Specifications
- Form factor
- Inclined 4-Channel EDS Detector
- Performance
- Up to 2,400,000 cps output count rate (OCR)
- Output Count Rate (OCR)
- Up to 2,400,000 cps
- Detector Type
- Inclined 4-Channel EDS Detector
- Sensor Technology
- Silicon Drift Detector (SDD)
Added by AntSpace from public sources (bruker.com).